Homogeneous flooring(Also known as hospital vinyl flooring) is often used in hospitals because of its durability, hygiene and ease of maintenance. The following are some of the main applications for homogeneous flooring in hospitals: Wards, work areas and corridors: The durability and abrasion resistance of homogeneous flooring makes it suitable for high-traffic areas such as corridors and aisles. Its seamless installation provides a smooth and easy to clean surface. Laboratories and operating theatres: Hygiene is critical in operating theatres, and homogeneous flooring with heat-welded seams helps create a seamless hygienic environment. The smooth surface allows thorough cleaning and reduces the risk of microbial growth. In laboratory environments, where chemical resistance and cleanliness are critical, homogeneous flooring is often chosen. Diagnostic imaging rooms: able to withstand the weight and movement of heavy medical equipment
The fireproof grade reaches B1. It has high flame retardant property and can effectively stop the spread of flame.
Homogeneous flooring adopts a single structure, improves the thickness of the wear-resistant layer, and adopts a reasonable friction coefficient to skillfully disperse walking pressure and shock absorption.
The homogeneous floor surface layer adopts PUR technology, which has good anti-fouling and waterproofing performance and can reduce the frequency of daily maintenance such as waxing and cleaning, and reduce the cost of regular maintenance.
Antibacterial activity(inhibits growth > 92%)
TVOC ≤10 u g/m'after 28 days
Standard | Homogeneous floor | |
Surface Treatment | - | PUR |
Total Thickness | ISO 24346:2006(R2015) | 2.0(2.5/3.0/4.0mm) |
Thickness of Wear layer | ISO 24346:2006(R2015) | 2mm |
Size:Lenght/Width | ISO 24341:2006 | 2.0m*20m |
Total Weight | ISO 23997:2007(R2018) | 3100g/㎡ |
SAFETY CRITERIA
Antistatic | EN1815:2016 | 0.1 kV |
Electric properties | SJ/T11236-2001/EN1081 | / |
Decay time | SJ/T10694-2006(IVI<100V) | / |
Charge voltage | SJ/T10694-2006(IVI<100V) | / |
Fire Rating | EN13501-1 | B-S1 |
Anti-bacterial | ISO 22196:2011 | 99.50% |
Residual Indentation | EN 433:1994 | 0.06mm |
Abrasion Resistance | GB/T11982.1-2015 | T |
Dynamic coefficient of friction | EN 13893:2002 | 0.35 |
Anti-Slip Property | DIN 51130:2014-02 | R9 |
PRODUCT PERFORMANCE
Dimensional stability | GB/T11982.1-2015 | ≤0.2% |
Color fastness | ISO105-B02:2014 | ≥6 |
Resistance to chenmicals | ISO 26987:2008 | good |
Bend resistance | GB/T11982.1-2015 | No damage |
Castor Wheel Test | GB/T11982.1-2015 | Excellent |
Formaldehyde emission | GB/T 17657-2013 | E0 |
Factory direct sales
10+ Years
200+ employees
More than 78 quality inspections,4 patents
7500+ customers,200+ agents
30,000 square metres daily output
Homogeneous flooring (also known as hospital vinyl flooring), can be used in operating theatres, hospital halls, wards, CT rooms, hospital offices and other rooms.
Before the installation of Homogeneous flooring will be laid flat for 1 day so that the PVC floor is fully adapted to the environment.
01. Check whether the floor is level or not. If it is not level, you need to do self-leveling.
02. Clean the floor and apply the glue. Then use the equipment to blow the floor for about 30 minutes, so that the adhesive glue reaches the highest viscosity.
03. Lay the homogeneous flooring in order, and cut off the overlapping excess.
04. Use the machine to cut the groove between the homogeneous flooring, so that it is easy to weld the wires into the center seam.
05. Use the machine to embed the welding wires into the groove and cut off the excess welding wires. Make the homogeneous flooring seamless.
Clean the floor from excess waste homogeneous flooring.
Roll with kraft paper ourside. Pallets are necessary for LCL.
Customization is welcomed.
We are a factory with nearly 20 years of history.
The factory has independent office space and 30,000 square meters of production workshops with 200 employees and 6 production lines,passing more than 100 tests and obtaining 4 patents.
Farfly has more than 7500 customers and 200 agents all over the world and is the long-term trusted quality manufacturer of Li Ning, Adidas and other companies.
Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Production Process of Hospital Vinyl Flooring
Introducing the production line of hospital vinyl flooring(also called medical vinyl flooring), designed to meet the rigorous demands of healthcare environments. Our state-of-the-art manufacturing process ensures the highest standards of durability, hygiene, and ease of maintenance, making our vinyl flooring the ideal choice for hospitals.For example, it can be used in operating theatres, hospital halls, wards, CT rooms, hospital offices and other rooms.
Production Process
Our production line for hospital vinyl flooring involves several meticulous steps to ensure the highest quality:
Material Selection:
High-quality raw materials are chosen for their durability and resistance properties.
Strict quality control measures are applied to ensure consistency.
Manufacturing:
Advanced machinery and technology are used to produce homogeneous vinyl sheets and rolls.
Introducing the production line of vinyl flooring for hospitals
Precision engineering ensures uniform thickness and texture.
Seamless Finishing:
Heat-welding techniques are employed to create seamless joints.
Ensures a smooth, uninterrupted surface that is easy to clean.
Quality Assurance:
Rigorous testing for durability, chemical resistance, and hygiene.
Each batch undergoes thorough inspection before being approved for distribution.
|
Conclusion
Our hospital vinyl flooring production line is dedicated to providing the highest quality flooring solutions for healthcare facilities. With a focus on durability, hygiene, and ease of maintenance, our vinyl flooring meets the stringent requirements of modern hospitals, ensuring a safe and clean environment for patients and healthcare providers alike.